PCE Deutschland occupational health and safety meter for formaldehyde PCE-VOC 1 Thumbnail
PCE Deutschland occupational health and safety meter for formaldehyde PCE-VOC 1 Thumbnail
PCE Deutschland occupational health and safety meter for formaldehyde PCE-VOC 1 Thumbnail
PCE Deutschland occupational health and safety meter for formaldehyde PCE-VOC 1 Thumbnail
PCE Deutschland occupational health and safety meter for formaldehyde PCE-VOC 1 Thumbnail
PCE Deutschland occupational health and safety meter for formaldehyde PCE-VOC 1 Thumbnail
PCE Deutschland occupational health and safety meter for formaldehyde PCE-VOC 1 Thumbnail

 
PCE Deutschland occupational health and safety meter for formaldehyde PCE-VOC 1
zoom_in
zoom_out
fullscreen
PCE Instruments brandlogo
-23%

PCE Deutschland occupational health and safety meter for formaldehyde PCE-VOC 1

Artikelnummer: T-910328
201,95 € (inkl. 19% skat, ekskl. forsendelsesomkostninger)
169,71 € (ekskl. moms, ekskl. forsendelsesomkostninger)
261,69 € MSRP
På lager,
klar til forsendelse inden for 48 timer
 
Stil et spørgsmål
Indhold:
1 Stk.
Forsendelse:
The shipping costs for Danmark could not be calculated automatically.
Udbyder:
Salg og levering før ToolTeam®
Betalingsmetoder:
Returforsendelser:
Sikkerhed:

Produktdata

Fabrikant:
PCE Deutschland GmbH
Tilstand:
Ny
Artikelnummer:
T-910328
SKU producent:
PCE-VOC 1
GTIN -kode (EAN):
4250348717351
Vægt:
0,24 Kg
Alle oplysninger vedrørende produkter fra PCE Deutschland GmbH. Der tages forbehold for tekniske og optiske ændringer og fejl fra producentens side. This page has been machine-translated, the original german version can be found here, please also note the Oversættelse Ansvarsfraskrivelse.

Produktbeskrivelse

The VOC tester PCE-VOC 1 is used for the approximate measurement of VOC (TVOC; volatile organic compounds) and HCHO (formaldehyde). The VOC tester PCE-VOC 1 is particularly suitable for checking indoor air quality. The TVOC provides information about the indoor air quality. This VOC tester is characterized by its large display and easy operation. Only three buttons on the VOC measuring device allow you to work quickly with the PCE-VOC 1. In addition to displaying the measured values, the user can see the alarm visually on the display. The display turns red when a critical VOC or HCHO reading has been reached. The air quality reading can be displayed by the VOC tester in mg/m³ or in PPM. The VOC test device PCE-VOC 1 has a lithium-polymer battery that ensures operation for several hours. The built-in battery is charged via the power pack, which can be connected to the VOC tester. Volatile Organic Compounds (VOC)

What are VOCs? The English abbreviation VOC (Volatile Organic Compounds) refers to the group of volatile organic compounds. VOC describes gaseous and vaporous substances of organic origin in the air. These include, for example, hydrocarbons, alcohols, aldehydes and organic acids. Many solvents, liquid fuels and synthetically manufactured substances can occur as VOCs, but also numerous organic compounds formed in biological processes. Many hundreds of different individual compounds can occur together in the air. What are sources of VOCs? VOCs arise from very different sources. Biological processes can be sources of outside air, for example plant metabolism, putrefaction and degradation processes. Other outdoor air sources are technical processes in which substances are produced from incomplete combustion (particularly vehicle exhaust fumes) or as volatile by-products from industrial and commercial processes. Possible indoor sources are products and materials for building construction and interior decoration (e.g. floor, wall and ceiling materials, paints, varnishes, adhesives, furniture and decorative materials). Care, cleaning and hobby products are also important, as well as tobacco smoking, even food preparation and human metabolism. Compared to outdoor air sources, indoor sources in Central Europe are generally of significantly greater importance to health, since people are mainly in buildings. In addition, the distance to the VOC sources indoors is usually smaller. VOCs from the outside air can also get into the interior. As a rule, however, the original indoor concentrations are reduced during ventilation.

How do VOCs get into the air? When solvents or liquid fuels evaporate and liquid or pasty products dry, large quantities of VOCs escape into the ambient air. The spread of various accompanying substances that are not firmly integrated into products is less obvious. They can be released slowly from the product surface into the air and continuously replenished from the inside of the product to the surface (material emission). This applies, for example, to residual solvents and building blocks in plastics (monomers), auxiliaries such as plasticizers, solubilizers, antioxidants, stabilizers and catalysts from the production process, as well as accompanying substances such as fragrances, flame retardants and biocidal active ingredients. Terpenes are also typical VOCs. They are released into the air from materials and products of natural origin, such as wood. VOCs are also formed as reaction products, for example between oxygen, ozone or water with ingredients of natural origin, such as those found in wood and vegetable oils. What health effects can VOCs have? The individual VOC concentrations are usually very low and there is no risk of damage to health. Concentrations that cause health impairments can occur immediately after construction and extensive renovation work, as well as in the event of improper processing and the massive use of unsuitable products. Odor nuisance, irritation and symptoms that cannot be directly assigned to a disease have been described as acute effects on humans. These effects must be avoided, as must possible chronic effects that scientists have derived from toxicological assessments; particularly naturally carcinogenic, mutagenic and reprotoxic effects. If such effects of substances are known, they may no longer be used in the end product (Chemicals Prohibition Ordinance). However, it cannot be completely ruled out that traces of VOC with such a potential effect are contained in the product if they were present in uncontrolled pre-products or recycled materials.

How can VOCs be reduced? Consumers should choose low-emission products and materials. They can use environmental labels such as the Blue Angel as a guide. In the case of more extensive construction or renovation measures, you can see whether the materials have been tested according to the AgBB evaluation scheme. Both materials with a recognized eco-label and those that have been successfully tested according to the AgBB scheme guarantee that the possible VOC emissions are reduced to a low level. If health problems occur in the home and a connection with VOCs is suspected, finding the source is usually difficult. Indoor air measurements and emission measurements on different materials are very time-consuming and often do not bring the desired clarity. Residents should therefore seek professional advice. You can find experts through municipal health and environmental authorities, the chambers of industry and commerce or on the Internet. Experts can often determine the probable source of VOCs by simply inspecting the home and interviewing residents. Once the sources of the VOC pollution have been clearly determined, a decision must be made individually about their elimination - depending on the type and extent of the possible health impairment, the level and expected reduction in the VOC concentration and the costs. Again, professional advice should be included as to whether and how to remove, contain or treat the VOC sources. In principle, it is always helpful to reduce a VOC concentration indoors by ventilation.

Relaterede resultater

Komplette kataloger

Tilbuddet er udelukkende rettet mod erhvervskunder, virksomheder, offentlige institutioner, håndværkere og freelancere. Alle priser i kataloger er eksklusive moms, forsendelsesomkostninger og eventuelle tillæg.
Producenten er kun ansvarlig for indhold, pris og artikeldetaljer for produkterne og tilbuddene i katalogerne. Med forbehold for tekniske og optiske ændringer og fejl fra producentens side.

Produktforslag

-23% PCE Instruments PCE Deutschland work safety measuring device PCE-VA 20
work safety measuring device PCE-VA 20
PCE-VA 20
261,65 €
ekskl. forsendelsesomkostninger
339,05 € MSRP
-23% PCE Instruments PCE Deutschland occupational health and safety measuring device PCE-HLD 10
occupational health and safety measuring device PCE-HLD 10
PCE-HLD 10
321,35 €
ekskl. forsendelsesomkostninger
416,39 € MSRP
-23% PCE Instruments PCE Deutschland occupational health and safety measuring device PCE-GA 10
occupational health and safety measuring device PCE-GA 10
PCE-GA 10
171,65 €
ekskl. forsendelsesomkostninger
222,40 € MSRP
-23% PCE Instruments PCE Deutschland work safety measuring device PCE-SLM 10
work safety measuring device PCE-SLM 10
PCE-SLM 10
246,98 €
ekskl. forsendelsesomkostninger
319,99 € MSRP
-22% PCE Instruments PCE Deutschland Occupational safety measuring device PCE-MSL 2BT
Occupational safety measuring device PCE-MSL 2BT
PCE-MSL 2BT
69,40 €
ekskl. forsendelsesomkostninger
89,15 € MSRP
-23% PCE Instruments PCE Deutschland occupational health and safety measuring device PCE-GA 12
occupational health and safety measuring device PCE-GA 12
PCE-GA 12
199,20 €
ekskl. forsendelsesomkostninger
258,10 € MSRP
-24% PCE Instruments PCE Deutschland Occupational safety measuring device PCE-VM 22
Occupational safety measuring device PCE-VM 22
PCE-VM 22
2.444,55 €
ekskl. forsendelsesomkostninger
3.196,20 € MSRP
-23% PCE Instruments PCE Deutschland work safety measuring device PCE-SLD 10
work safety measuring device PCE-SLD 10
PCE-SLD 10
330,55 €
ekskl. forsendelsesomkostninger
428,29 € MSRP
-23% PCE Instruments PCE Deutschland PCE-323 Bluetooth sound level meter 30 - 130 dB | Class 2 | Android | iOS | Live view | free app
PCE-323 Bluetooth sound level meter 30 - 130 dB | Class 2 | Android | iOS | Live view | free app
PCE-323
229,55 €
ekskl. forsendelsesomkostninger
297,39 € MSRP
-23% PCE Instruments PCE Deutschland PCE-EMF 40 magnetic field tester up to 2000 V/m | 3-axis measurement | for low and high frequencies | 2.4’’ display
PCE-EMF 40 magnetic field tester up to 2000 V/m | 3-axis measurement | for low and high frequencies | 2.4’’ display
PCE-EMF 40
458,25 €
ekskl. forsendelsesomkostninger
593,69 € MSRP
-23% PCE Instruments PCE Deutschland work safety measuring device PCE-LMD 10
work safety measuring device PCE-LMD 10
PCE-LMD 10
201,05 €
ekskl. forsendelsesomkostninger
260,49 € MSRP
2 Variants
-24% PCE Instruments PCE Deutschland Sound Level Dosimeter PCE-MND 10 Occupational Health and Safety Measurement |IEC 61252:2002 |70-40 dB (A,C)|90-140 dB (Z)
Sound Level Dosimeter PCE-MND 10 Occupational Health and Safety Measurement |IEC 61252:2002 |70-40 dB (A,C)|90-140 dB (Z)
PCE-MND 10
905,50 €
ekskl. forsendelsesomkostninger
1.183,95 € MSRP
-23% PCE Instruments PCE Deutschland occupational health and safety measuring device PCE-WB 20SD
occupational health and safety measuring device PCE-WB 20SD
PCE-WB 20SD
508,75 €
ekskl. forsendelsesomkostninger
659,15 € MSRP
-24% PCE Instruments PCE Deutschland occupational health and safety measuring device PCE-VM 20
occupational health and safety measuring device PCE-VM 20
PCE-VM 20
1.720,10 €
ekskl. forsendelsesomkostninger
2.248,99 € MSRP