zoom_in
zoom_out
fullscreen
-23%
PCE Deutschland voltage data logger PCE-VR 10
Sku: T-910329
265,42 € (excl. legal VAT, excl. Shipping)
343,91 € MSRP
In stock,ready for shipping within 48h
Content:
1 Piece
Shipping:
The shipping costs for United Kingdom could not be calculated automatically.
Provider:
Sales and delivery by ToolTeam®
Payment methods:
Returns:
Security:
Product data
Manufacturer:
PCE Deutschland GmbH
Condition:
NEW
Sku:
T-910329
SKU manufacturer:
PCE-VR 10
GTIN Code (EAN):
4250348719355
Weight:
0,28 Kg
All information relating to products from PCE Deutschland GmbH. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
The Voltage Data Logger from PCE Instruments is used to record up to three input channels of 0 ... 3000 mV signals via three input channels. The voltage data logger stores the measured voltages on an SD card in Excel format. To record also higher voltages in the range between 0 ... 10 V a voltage divider can be used. The measured voltages are transmitted via plug-in terminals to the data logger, which displays the corresponding values directly on the display and simultaneously stores them on the memory with the associated time stamp. A scaling of the measuring signal is not necessary, because the measuring values are stored directly as mV-measuring value. Scaling can then be conveniently performed manually in Excel.
The voltage data logger thus determines the pure raw data of the sensors whereby any further processing and data evaluation can be carried out very flexibly via spreadsheet programs such as Excel. In addition to storing the measured values, the voltage data logger displays the values of the respective voltage channels on the large backlit LC display. The maximum resolution is 0.1 mV with an accuracy of 0.5 % + 2 mV. The voltage data logger is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values the data logger from PCE Instruments can be connected to the PC via the serial interface. The storage intervals are adjustable in several steps between 1 second and 600 seconds. Thanks to the robust housing, the voltage data logger can be placed on a table or mounted on a wall. This allows mobile measurements at different locations as well as stationary measurements, e.g. if permanent recordings are to be made at only one plant.
Areas of application for the data logger for voltage If measured values and data have to be recorded, compared and later documented over longer periods of time, data loggers which are usually specially designed for the corresponding variables are suitable in most cases. Often it concerns variables such as temperature, humidity, pressure, energy, light, pollutants or current and voltage. Data loggers consist of a storage medium such as an SD card, an interface (USB, Bluetooth, WLAN...) and at least one channel for the corresponding measured variable. Often there is also the possibility to record different measured variables simultaneously via several channels. The voltage data logger from PCE Instruments is specially designed for the field of electrical voltage measurement and is therefore suitable for parallel recording of voltages on a maximum of three voltage channels.
The voltage data logger is used to record e.g. sensor data which can be read out via a voltage output. The measuring range of up to 3000 mV can be extended for sensors with higher voltages up to 10 V via a voltage divider (see optional accessories). If, for example, physical variables such as temperature, pressure and level are to be recorded and compared simultaneously in a system, the corresponding sensors can be connected to the data logger in order to display and document the changes and mutual dependencies of the three variables after the measurement. The voltage data logger can also be used to compare identical sensors at a measuring point. In this way, sensor errors can be directly excluded before permanent installation and measurement. Air pressures before and after filters can also be checked with suitable sensors in order to test the filter function. The data loggers for voltage are therefore suitable for a wide range of applications in industry, maintenance and repair or research and development.
The voltage data logger thus determines the pure raw data of the sensors whereby any further processing and data evaluation can be carried out very flexibly via spreadsheet programs such as Excel. In addition to storing the measured values, the voltage data logger displays the values of the respective voltage channels on the large backlit LC display. The maximum resolution is 0.1 mV with an accuracy of 0.5 % + 2 mV. The voltage data logger is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values the data logger from PCE Instruments can be connected to the PC via the serial interface. The storage intervals are adjustable in several steps between 1 second and 600 seconds. Thanks to the robust housing, the voltage data logger can be placed on a table or mounted on a wall. This allows mobile measurements at different locations as well as stationary measurements, e.g. if permanent recordings are to be made at only one plant.
Areas of application for the data logger for voltage If measured values and data have to be recorded, compared and later documented over longer periods of time, data loggers which are usually specially designed for the corresponding variables are suitable in most cases. Often it concerns variables such as temperature, humidity, pressure, energy, light, pollutants or current and voltage. Data loggers consist of a storage medium such as an SD card, an interface (USB, Bluetooth, WLAN...) and at least one channel for the corresponding measured variable. Often there is also the possibility to record different measured variables simultaneously via several channels. The voltage data logger from PCE Instruments is specially designed for the field of electrical voltage measurement and is therefore suitable for parallel recording of voltages on a maximum of three voltage channels.
The voltage data logger is used to record e.g. sensor data which can be read out via a voltage output. The measuring range of up to 3000 mV can be extended for sensors with higher voltages up to 10 V via a voltage divider (see optional accessories). If, for example, physical variables such as temperature, pressure and level are to be recorded and compared simultaneously in a system, the corresponding sensors can be connected to the data logger in order to display and document the changes and mutual dependencies of the three variables after the measurement. The voltage data logger can also be used to compare identical sensors at a measuring point. In this way, sensor errors can be directly excluded before permanent installation and measurement. Air pressures before and after filters can also be checked with suitable sensors in order to test the filter function. The data loggers for voltage are therefore suitable for a wide range of applications in industry, maintenance and repair or research and development.
Hinweise zur Batterieentsorgung:
Da in unseren Sendungen Batterien und Akkus enthalten sein können, sind wir nach dem Batteriegesetz (BattG) verpflichtet, Sie auf Folgendes hinzuweisen:
- Batterien und Akkus dürfen nicht im Hausmüll entsorgt werden, sondern Sie sind zur Rückgabe gebrauchter Batterien und Akkus gesetzlich verpflichtet.
- Altbatterien können Schadstoffe enthalten, die bei nicht sachgemäßer Lagerung oder Entsorgung die Umwelt oder Ihre Gesundheit schädigen können. Batterien enthalten aber auch wichtige Rohstoffe wie z.B. Eisen, Zink, Mangan oder Nickel und können verwertet werden.
- Sie können die Batterien nach Gebrauch entweder an uns zurücksenden oder in unmittelbarer Nähe (z.B. im Handel oder in kommunalen Sammelstellen oder in unserem Lager) unentgeltlich zurückgeben.
- Die Abgabe in Verkaufsstellen ist dabei für Endnutzer auf die übliche Mengen sowie solche Altbatterien beschränkt, die der Vertreiber als Neubatterien in seinem Sortiment führt oder geführt hat.
- Das Zeichen mit der durchgekreuzten Mülltonne bedeutet, dass Sie Batterien und Akkus nicht im Hausmüll entsorgen dürfen
Unter diesen Zeichen finden Sie zusätzlich nachstehende Symbole mit folgender Bedeutung:
- Pb = Batterie enthält mehr als 0,004 Masseprozent Blei
- Cd = Batterie enthält mehr als 0,002 Masseprozent Cadmium
- Hg = Batterie enthält mehr als 0,0005 Masseprozent Quecksilber
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Product suggestions
-21%
PCE-HT 70 humidity meter 0% RH..100% RH ±3% RH|Measurement/storage rate 1s/15 days|MB -40..85 °C
PCE-HT 70
51,00 €
64,92 € MSRP
-23%
PCE-HT110 Humidity Meter (Hygrometer)| 2-channel data logger | Long-term measurement of temperature + humidity
PCE-HT110
184,37 €
238,90 € MSRP
-24%
data logger PCE-VM 5000
PCE-VM 5000
1.694,03 €
2.214,92 € MSRP
-24%
data logger PCE-T 1200
PCE-T 1200
840,46 €
1.098,90 € MSRP
-23%
WLAN hygrometer PCE-THT 10 | Memory for 12800 measuring points | -20 ... 60 °C | 0 ... 99.9% RH | Color display
PCE-THT 10
174,36 €
225,88 € MSRP
-24%
shock data logger PCE-VDR 10
PCE-VDR 10
581,18 €
759,91 € MSRP
-24%
sound level meter PCE-NDL 10 with data logger | Frequency A+C | Interval 1-3600 s | SD card slot | USB
PCE-NDL 10
562,06 €
734,92 € MSRP
-23%
data logger PCE-HPT 1
PCE-HPT 1
362,68 €
469,91 € MSRP
-23%
Cryo data logger PCE-LTD 100
PCE-LTD 100
184,37 €
238,90 € MSRP
-23%
PCE-322A Sound Level Meter 26.. 130 dB|Res. 0.1dB|Exactly ±1.5dB|ref. 94 dB at 1kHz|Fr. 31.5Hz..8kHz
PCE-322A
127,27 €
164,92 € MSRP
-23%
laboratory data logger PCE-HT 300
PCE-HT 300
354,19 €
458,91 € MSRP
-23%
data logger PCE-VDL 16I for machine monitoring
PCE-VDL 16I
192,10 €
248,90 € MSRP
-22%
PCE-HT 112 climate logger for temperature & humidity | fast reading via USB | 25920 reading memory
PCE-HT 112
85,59 €
109,91 € MSRP
-23%
data logger PCE-PHD 1-LF for conductivity
PCE-PHD 1-LF
324,08 €
419,91 € MSRP
-22%
PCE-HT 72 PDF data logger 0% RH..100% RH ±0.1% RH|meas./mem. 2s to 24h|20010 measured values|MR -30..60 °C
PCE-HT 72
65,34 €
83,91 € MSRP
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
PCE Deutschland voltage data logger PCE-VR 10
The Voltage Data Logger from PCE Instruments is used to record up to three input channels of 0 ... 3000 mV signals via three input channels. The voltage data logger stores the measured voltages on an SD card in Excel format. To record also higher voltages in the range between 0 ... 10 V a voltage divider can be used. The measured voltages are transmitted via plug-in terminals to the data logger, which displays the corresponding values directly on the display and simultaneously stores them on the memory with the associated time stamp. A scaling of the measuring signal is not necessary, because the measuring values are stored directly as mV-measuring value. Scaling can then be conveniently performed manually in Excel.
The voltage data logger thus determines the pure raw data of the sensors whereby any further processing and data evaluation can be carried out very flexibly via spreadsheet programs such as Excel. In addition to storing the measured values, the voltage data logger displays the values of the respective voltage channels on the large backlit LC display. The maximum resolution is 0.1 mV with an accuracy of 0.5 % + 2 mV. The voltage data logger is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values the data logger from PCE Instruments can be connected to the PC via the serial interface. The storage intervals are adjustable in several steps between 1 second and 600 seconds. Thanks to the robust housing, the voltage data logger can be placed on a table or mounted on a wall. This allows mobile measurements at different locations as well as stationary measurements, e.g. if permanent recordings are to be made at only one plant.
Areas of application for the data logger for voltage If measured values and data have to be recorded, compared and later documented over longer periods of time, data loggers which are usually specially designed for the corresponding variables are suitable in most cases. Often it concerns variables such as temperature, humidity, pressure, energy, light, pollutants or current and voltage. Data loggers consist of a storage medium such as an SD card, an interface (USB, Bluetooth, WLAN...) and at least one channel for the corresponding measured variable. Often there is also the possibility to record different measured variables simultaneously via several channels. The voltage data logger from PCE Instruments is specially designed for the field of electrical voltage measurement and is therefore suitable for parallel recording of voltages on a maximum of three voltage channels.
The voltage data logger is used to record e.g. sensor data which can be read out via a voltage output. The measuring range of up to 3000 mV can be extended for sensors with higher voltages up to 10 V via a voltage divider (see optional accessories). If, for example, physical variables such as temperature, pressure and level are to be recorded and compared simultaneously in a system, the corresponding sensors can be connected to the data logger in order to display and document the changes and mutual dependencies of the three variables after the measurement. The voltage data logger can also be used to compare identical sensors at a measuring point. In this way, sensor errors can be directly excluded before permanent installation and measurement. Air pressures before and after filters can also be checked with suitable sensors in order to test the filter function. The data loggers for voltage are therefore suitable for a wide range of applications in industry, maintenance and repair or research and development. 4250348719355-4147 4250348719355 https://www.toolteam.com/en-GB/pce-deutschland-voltage-data-logger-pce-vr-10-t-910329-4250348719355?dc=GB&cu=EUR 2024-11-18 265.42 DE 14
The voltage data logger thus determines the pure raw data of the sensors whereby any further processing and data evaluation can be carried out very flexibly via spreadsheet programs such as Excel. In addition to storing the measured values, the voltage data logger displays the values of the respective voltage channels on the large backlit LC display. The maximum resolution is 0.1 mV with an accuracy of 0.5 % + 2 mV. The voltage data logger is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values the data logger from PCE Instruments can be connected to the PC via the serial interface. The storage intervals are adjustable in several steps between 1 second and 600 seconds. Thanks to the robust housing, the voltage data logger can be placed on a table or mounted on a wall. This allows mobile measurements at different locations as well as stationary measurements, e.g. if permanent recordings are to be made at only one plant.
Areas of application for the data logger for voltage If measured values and data have to be recorded, compared and later documented over longer periods of time, data loggers which are usually specially designed for the corresponding variables are suitable in most cases. Often it concerns variables such as temperature, humidity, pressure, energy, light, pollutants or current and voltage. Data loggers consist of a storage medium such as an SD card, an interface (USB, Bluetooth, WLAN...) and at least one channel for the corresponding measured variable. Often there is also the possibility to record different measured variables simultaneously via several channels. The voltage data logger from PCE Instruments is specially designed for the field of electrical voltage measurement and is therefore suitable for parallel recording of voltages on a maximum of three voltage channels.
The voltage data logger is used to record e.g. sensor data which can be read out via a voltage output. The measuring range of up to 3000 mV can be extended for sensors with higher voltages up to 10 V via a voltage divider (see optional accessories). If, for example, physical variables such as temperature, pressure and level are to be recorded and compared simultaneously in a system, the corresponding sensors can be connected to the data logger in order to display and document the changes and mutual dependencies of the three variables after the measurement. The voltage data logger can also be used to compare identical sensors at a measuring point. In this way, sensor errors can be directly excluded before permanent installation and measurement. Air pressures before and after filters can also be checked with suitable sensors in order to test the filter function. The data loggers for voltage are therefore suitable for a wide range of applications in industry, maintenance and repair or research and development. 4250348719355-4147 4250348719355 https://www.toolteam.com/en-GB/pce-deutschland-voltage-data-logger-pce-vr-10-t-910329-4250348719355?dc=GB&cu=EUR 2024-11-18 265.42 DE 14